Coolant freeze point and boiling point chart
Ethylene glycol concentration from 0 to 100 %, with freeze point and boiling point in °C and °F — plus the pressure-cap correction that decides whether an engine actually boils over.
This is the table we blend against. It gives the freeze point and atmospheric boiling point for every practical glycol concentration, the same figures in Fahrenheit, and the boiling point once a pressurised cap is fitted.
Everything except the °C source values is derived: the Fahrenheit column and the 15 psi boiling point are calculated from the Celsius figures, so the rows cannot disagree with each other.
The four numbers most people need
- 50 / 50 mix
- − 37 °C / − 35 °F freeze, 107 °C atmospheric boil
- 15 psi cap
- adds about 26 °C — the 50 / 50 mix then boils near 133 °C
- Peak protection
- 70 % glycol, about − 55 °C. More glycol freezes sooner
- Usable band
- 30 – 70 % glycol. Below 30 % you are buying corrosion protection only
Freeze and boiling point by ethylene glycol concentration
Ethylene glycol and water mixtures at sea level (101.3 kPa). The fourth column is the atmospheric boiling point; the fifth adds a 15 psi (1.0 bar) pressure cap. Figures are rounded to the nearest degree — interpolate between rows for other mixtures.
| Glycol by volume | Freeze point °C | Freeze point °F | Boil point °C (atmospheric) | Boil point °C (15 psi cap) |
|---|---|---|---|---|
| 0 % | 0 °C | 32 °F | 100 °C | 126 °C |
| 10 % | − 4 °C | 25 °F | 101 °C | 127 °C |
| 20 % | − 9 °C | 16 °F | 102 °C | 128 °C |
| 30 % | − 15 °C | 5 °F | 104 °C | 130 °C |
| 33 % | − 18 °C | 0 °F | 105 °C | 131 °C |
| 40 % | − 24 °C | − 11 °F | 106 °C | 132 °C |
| 50 % | − 37 °C | − 35 °F | 107 °C | 133 °C |
| 55 % | − 43 °C | − 45 °F | 109 °C | 135 °C |
| 60 % | − 52 °C | − 62 °F | 111 °C | 137 °C |
| 65 % | − 54 °C | − 65 °F | 113 °C | 139 °C |
| 70 % | − 55 °C | − 67 °F | 115 °C | 141 °C |
| 80 % | − 48 °C | − 54 °F | 120 °C | 146 °C |
| 90 % | − 29 °C | − 20 °F | 140 °C | 166 °C |
| 100 % | − 13 °C | 9 °F | 197 °C | 223 °C |
Swipe the table sideways to see every column.
The shaded rows are the concentrations most vehicles actually run; 30 % to 70 % is the usable band.
Read the curve, not a single row: freeze protection peaks at about 70 % glycol (− 55 °C) and then gets worse. Neat glycol freezes near − 13 °C, so a drum of undiluted antifreeze is not a substitute for a correctly mixed coolant.
What a pressure cap adds
System pressure raises the boiling point of the mixture, not of the water in it. Every 1 psi adds roughly 1.7 °C. Figures below are for a 50 % glycol mix at 107 °C atmospheric.
| Cap rating (psi) | Pressure (bar) | Added to boiling point | 50 / 50 mix boils at |
|---|---|---|---|
| 0 psi | 0.0 | — | 107 °C |
| 7 psi | 0.5 | + 12 °C | 119 °C |
| 15 psi | 1.0 | + 26 °C | 133 °C |
| 21 psi | 1.4 | + 36 °C | 143 °C |
This is why a failed cap is a real fault and not a cosmetic one. A cap that no longer holds pressure silently takes 25 °C of boil-over protection with it — the system will boil in traffic on a hot day while the coolant itself still tests correctly.
Ready-to-use grades against climate
BOLITCH ready-to-use coolant is supplied as a finished mix, so the freeze point on the label is the freeze point in the engine. Grades from 0 °C to − 45 °C; other freeze points are available to order.
| Grade | Typical climate band | Where it is specified |
|---|---|---|
| 0 °C(32 °F) | No freeze protection — markets that never see frost | Southeast Asia, West Africa, coastal Middle East, South Asia |
| − 25 °C(− 13 °F) | Light to hard frost, subtropical highlands, mild continental winters | South African highveld, southern Brazil, northern India, Türkiye |
| − 35 °C(− 31 °F) | Continental winter, cold chain and refrigerated transport | Northern China, Eastern Europe, Central Asia |
| − 45 °C(− 49 °F) | Severe winter, mining and fleet operations above 45° latitude | Russia, Mongolia, Kazakhstan, Canada |
Swipe the table sideways to see every column.
Atmospheric boiling points across the range are 101 – 110 °C, measured per grade; the exact figure for a grade is stated on its TDS. Long-life OAT grades carry a 5 year / 300,000 km service life.
How to read the chart without getting it wrong
Four mistakes account for most of the coolant problems we are asked about — and three of them come from misreading exactly this table.
Measure the mixture, not the bottle
A refractometer read at 20 °C is the only reliable check. Read the glycol scale, then convert through this table — the freeze-point scale printed on some refractometers disagrees with the table by several degrees.
30 % is the floor for freeze protection
Below roughly 30 % glycol you still have a corrosion-inhibited coolant, which is the correct product for a tropical market, but it has no meaningful freeze protection. Sell it as 0 °C, not as an all-season antifreeze.
More glycol is not more protection
Between 70 % and 100 % the freeze point climbs back toward − 13 °C, heat transfer falls, and cold-start viscosity rises. Over-concentrating is a real failure mode, not a safety margin.
The cap is part of the cooling system
The two boil point columns differ by 26 °C. If a vehicle overheats in traffic while the coolant tests at the right concentration, test the cap before touching the mixture.
Common questions
At what temperature does 50/50 coolant freeze?
A 50 % ethylene glycol mix freezes at approximately − 37 °C (− 35 °F). Its atmospheric boiling point is about 107 °C, which rises to roughly 133 °C once a 15 psi cap is fitted.
What is the boiling point of coolant with a pressure cap?
Every 1 psi of system pressure raises the boiling point by about 1.7 °C. A common 15 psi (1.0 bar) cap therefore adds about 26 °C, taking a 50 % mix from 107 °C to roughly 133 °C.
Is 100 % antifreeze better than a 50/50 mix?
No. Neat ethylene glycol freezes at about − 13 °C, transfers heat worse than a water mix and is more viscous when cold. Freeze protection peaks near 70 % glycol at about − 55 °C and gets worse above that.
How do I check the concentration in the workshop?
Use a refractometer, calibrated and read at 20 °C, against the glycol percentage scale — then convert with the table above. Hydrometers drift with temperature, and float-type testers are only accurate to a few degrees.
Cite this table
BOLITCH (Guangzhou Baolichi Automobile Technology Co., Ltd.). "Coolant Freeze Point and Boiling Point Chart." https://bolitch.com/tools/freeze-boil-point-chart
Free to quote with attribution. The URL is stable — link to it rather than copying the numbers, so the figures stay current.