Coolant Basics

Choosing the right antifreeze concentration for your climate (with freeze and boil point chart)

Ethylene glycol concentration against freeze and boil point, region by region guidance, and why over-concentrating coolant is just as bad as under-concentrating it.

7 min read

Antifreeze concentration is a trade-off. Glycol both lowers the freeze point and raises the boil point, which sounds like free protection — but the relationship is not linear, and pushing concentration too high makes freezing more likely, not less.

Freeze point and boil point by glycol concentration

Ethylene glycol by volumeFreeze pointAtmospheric boil point
0 % (plain water)0 °C100 °C
20 %− 9 °C102 °C
30 %− 15 °C104 °C
40 %− 24 °C106 °C
50 %− 37 °C107 °C
60 %− 52 °C111 °C
70 %− 55 °C115 °C
80 %− 48 °C120 °C
100 % (neat glycol)− 13 °C197 °C
Approximate values for ethylene glycol and water mixtures at atmospheric pressure. Follow the vehicle maker's specification where one exists.

What this means in practice

  • 50 % glycol, roughly − 37 °C, is the standard fill for most temperate and cold-climate passenger cars. It also lifts the atmospheric boil point to about 107 °C, which becomes roughly 125 – 135 °C once the system is pressurised.
  • 60 % glycol, roughly − 52 °C, suits severe winters and cold-chain or refrigerated transport.
  • Around 33 % glycol, roughly − 18 °C, is enough for mild-winter markets and still gives a useful boil margin. This is also close to the 'premixed' coolant sold in many markets.
  • Below about 30 % glycol you are no longer buying freeze protection; you are buying a corrosion-inhibited coolant. That is a legitimate product — much of Southeast Asia, Africa and South Asia needs exactly this — but it must be specified honestly as such.

The pressure cap changes everything

Every 1 psi of system pressure raises the boiling point of a 50 % glycol mix by roughly 1.7 °C. A typical 15 psi cap therefore adds about 25 °C, which is why an engine with a 107 °C atmospheric boil point will not boil until roughly 132 °C. This is the real mechanism behind 'boil-over protection' — the coolant and the cap work together.

It also means a failed cap silently destroys boil-over protection. A cap that no longer holds pressure can let a system boil at 110 °C instead of 132 °C, which is exactly the condition that boils over in traffic on a hot day.

Regional guidance

MarketTypical winter lowSensible grade
Southeast AsiaAbove + 10 °C0 °C coolant, boil-over focused, 30 % or less glycol
South Asia (plains)Above 0 °C0 °C to − 10 °C coolant, boil-over focused
South Asia (northern hills)− 5 to − 15 °C− 25 °C grade
Sub-Saharan Africa (tropical)Above + 5 °C0 °C coolant, boil-over focused
Southern Africa (inland winter)− 5 to − 12 °C− 25 °C grade
North Africa / Middle EastAbove 0 °C0 °C to − 10 °C, high boil margin
Central & Eastern Europe− 20 to − 30 °C− 37 °C grade
Northern Europe / Canada− 30 to − 45 °C− 45 °C grade

Open the mix calculator

Enter your lowest expected temperature and get the glycol ratio, freeze point and boil point you need.

Open

How to check what you actually have

Use a refractometer, not a float-type hydrometer. A refractometer reads the freeze point directly from a few drops and is not thrown off by the dye or by dissolved corrosion products the way a float gauge is. Check at every service, and record the reading — a freeze point that creeps upward between services means someone is topping up with water.